Service should be as dependable as the study material, and at GuideTorrent your HH0-300 order carries Hitachi HITACHI DATA SYSTEMS CERTIFIED EXPERT -REPLICATION SOLUTIONS ARCHITECT quality checks, instant delivery, 365 days of free updates, and support reachable by email or online chat at any hour.
Hitachi HH0-300 Exam Syllabus Topics:
| Section | Weight | Objectives |
|---|---|---|
| Topic 1: Implementation, Operation & Troubleshooting | 20% | - Monitoring replication status and performance - Common issues and resolution methods - Configuration and setup procedures - Failover and failback processes |
| Topic 2: Replication Concepts & Fundamentals | 20% | - Replication topologies and deployment models - Data protection and business continuity principles - RPO and RTO definitions and requirements - Synchronous vs asynchronous replication |
| Topic 3: Hitachi Replication Technologies | 35% | - Hitachi Command Suite management - Hitachi Universal Replicator (HUR) - Hitachi TrueCopy - Hitachi ShadowImage - Hitachi Global Active Device (GAD) |
| Topic 4: Architecture & Design | 25% | - Disaster recovery and high availability planning - Replication solution sizing and capacity planning - Interoperability with VSP and storage platforms - Network design and bandwidth requirements |
Hitachi HITACHI DATA SYSTEMS CERTIFIED EXPERT -REPLICATION SOLUTIONS ARCHITECT Materials That Go Where You Go
- Hitachi Replication Technologies (35%)
- Architecture & Design (25%)
- Replication Concepts & Fundamentals (20%)
Hitachi HITACHI DATA SYSTEMS CERTIFIED EXPERT -REPLICATION SOLUTIONS ARCHITECT Sample Questions:
What is the correct formula to calculate Hitachi Universal Replicator bandwidth sizing?
- A. Peak(Write MB/sec)+30%
- B. PeakRollingAverage(WriteMB/sec)+30%
- C. Peak(Write MB/sec)
- D. PeakRollingAverage(WriteMB/sec)
Correct Answer: D 🗳️
What are two examples of when a channel extender is required? (Choose two.)
- A. when using Fibre Channel compression
- B. when using replication over an extended distance
- C. when using replication in the same data center
- D. when Fibre Channel compression is not desired
Correct Answer: A,B 🗳️
A customer has a HUS 130 array and wants an asynchronous solution. The customer needs to understand which factors influence the TrueCopy Extended Distance cycle time.
Which two factors should be considered? (Choose two.)
- A. the maximum amount of data loss the operation could survive during a disaster
- B. reduced cycle time will always reduce your RPO
- C. the amount of data written to the P-Vol
- D. when splitting the pairs, the S-Vol will wait until the next update cycle so a reduced cycle time is important
Correct Answer: A,C 🗳️
A customer is conducting a test and has performed a planned failoverto their Hitachi Universal Replicator copies at the secondary site. They have confirmed their recovery capabilities and they are ready to return operations to the production site.
Which fallback procedure applies?
- A. Copy pace should be reduced until the resync copy is complete.
- B. Replication pairs must be suspended to allow changed tracks to be managed using the bitmap.
- C. A full initial copy will be required from the recovery storage back to the primary storage.
- D. Replication direction can be reversed without need for a full initial copy.
Correct Answer: D 🗳️
A customer is planning to replicate 36 TB of data using asynchronous replication. What are two primary considerations for sizing the expected solution? (Choose two.)
- A. Total number of IOPS for the environment
- B. The percentage of writes for the environment
- C. The amount of latency between the sites
- D. Number of disk units installed at the secondary site
Correct Answer: A,B 🗳️
Viewing page 1 out of 23 pages.
Viewing questions 1-5 out of 112 questions.


